TLD-600 double loop detector
1)Four-way output relays
2)Used for wherever vehicles have to be detected
3)Connection: 11-pin socket
Features:<ul>
Used for wherever vehicles have to be detected
Monitors and safe guards access ways or counting vehicles
Output signal can be used for controlling door and gate drive mechanisms
Operating barriers
Controls traffic light systems
Activates card dispensers in parking lots
Uses advanced microprocessor technology
Works in diverse environments
Four-way output relays
Two outputs are unlimited when corresponding loop is permanently covered
Others are multi-mode that can be set by users</ul>
Specifications:<ul>
Operating voltages: 220V AC ±10%
Power consumption: ≤5W
Relay output
Frequency range: 20 to 170kHz (4 grades adjustable)
Reaction time: 20ms
Sensitivity: 10 grades (adjustable)
Loop inductance: ideal 100 to 300μH (includes connecting wires)
Maximum loop inductance: 50 to 1,000μH (includes connecting wires)
Loop connecting wires: maximum 100m
Twisted at least 20 times per meter
Total resistance: <10Ω
Operating temperature: -30 to +75°C
Storage temperature: -40 to +85°C
Relative humidity: ≤95%
Connection: 11-pin socket
Shell: PC and ABS engineering plastics
Installation: DIN rail
Dimensions (L x W x H): 110 x 60 x 100mm
Net weight: 400g (including socket)</ul>